Multi-function temperature and humidity cabinet: multi-zone display, power-failure and high/low alarms

Baomingxiang multi-function cabinet: a graphic LCD listing temperature and humidity zone by zone, an internal battery so display and alarm survive a mains failure, four run lights with Auto/Off/Manual selectors, and a red sound-and-light beacon for over-temperature, under-temperature and power loss.

ModelBMX-1808Y
DisplayGraphic LCD, temp + humidity
ZonesMultiple, independent
AlarmsPower loss, high/low, sound+light
BackupInternal battery
Operation4 Auto/Off/Manual selectors
Taobaohttps://item.taobao.com/item.htm?id=768284879397
Our stores
Price and stock follow the store listings; bank transfer supported. For a configuration or an invoice, use the consultation on the right.

A white sheet-steel enclosure: graphic LCD in the upper door, four green run lights across the middle, four Auto / Off / Manual selectors below them, and a red sound-and-light beacon hanging on the side. The faceplate reads "intelligent multi-zone temperature and humidity controller", model BMX-1808Y.

Temperature and humidity on one screen

The display lists the zones line by line: 1: 26.0 °C, humidity 34.5%, 2: 25.9 °C, 3: 26.3 °C and so on, one zone per line with temperature and humidity side by side. For poultry, where humidity matters as much as heat, temperature alone is not enough — 80% relative humidity at a comfortable temperature feels like a different house, and respiratory problems follow. Putting both numbers on one meter is how you see whether a house is actually stuffy.

The battery line is what makes a power-failure alarm possible

One line on the display is battery voltage, reading 4.1 V here. That tells you the cabinet carries its own battery: when mains power goes, the meter and the alarm do not go quiet with it. A power failure on a farm is not a small event — fans stop, pads run dry, and in summer half an hour is enough to push a house up. The battery is what gives the alarm a chance to be sent.

Four selectors, four lights

Four green run indicators sit across the panel, each with a three-position selector beneath: Auto, Off, Manual. Lit means the channel is outputting, and turning to Manual runs that channel on its own. For manure cleaning, servicing or a trial run, the stockperson works at the cabinet instead of paging through a menu.

The red beacon

The lamp on the side is not decoration: on an over- or under-temperature event, or a power failure, it lights and sounds. A separate line on the display, "alarm: -----", stays blank when all is well and names the fault when there is one. Sound and light together — heard by whoever is working in the house by day, seen from a distance by whoever walks it at night.

Zones are independent

Each zone takes its own temperature and its own periods, and changing one does not move the others. One probe per house, one set of logic per air path: a brooding house and a finishing house can be set differently on the same cabinet, without retuning the whole site to suit one of them.

Enclosure and selection

Sheet-steel enclosure, white finish, wall mounted, with a door lock and an electric-shock label, cables entering top and bottom. Selection comes down to: how many zones, what each zone drives (fans, pads, heating), how many probe positions, and whether humidity is needed. Send those and we return a configuration and wiring diagram. Phone: +86 199 3789 6911.

Send us your site details, get a configuration the same day

Just three numbers: what you raise, how many, and how many houses. We work out outputs and fan count.

微信二维码 Scan on WeChat · send your house type
Or call 199 3789 6911

Questions about sizing? Leave a note

T P D